Loading...
Search for: vakilian--s
0.133 seconds

    Modeling and optimization of gelatin-chitosan micro-carriers preparation for soft tissue engineering: using response surface methodology

    , Article Materials Science and Engineering C ; Volume 75 , 2017 , Pages 545-553 ; 09284931 (ISSN) Radaei, P ; Mashayekhan, S ; Vakilian, S ; Sharif University of Technology
    2017
    Abstract
    Electrospray ionization is a wide spread technique for producing polymeric microcarriers (MCs) by applying electrostatic force and ionic cross-linker, simultaneously. In this study, fabrication process of gelatin-chitosan MCs and its optimization using the Response Surface Methodology (RSM) is reported. Gelatin/chitosan (G/C) blend ratio, applied voltage and feeding flow rate, their individual and interaction effects on the diameter and mechanical strength of the MCs were investigated. The obtained models for diameter and mechanical strength of MCs have a quadratic relationship with G/C blend ratio, applied voltage and feeding flow rate. Using the desirability curve, optimized G/C blend... 

    Evaluation of transformer core contribution to partial discharge electromagnetic waves propagation

    , Article International Journal of Electrical Power and Energy Systems ; Volume 83 , 2016 , Pages 40-48 ; 01420615 (ISSN) Rostaminia, R ; Saniei, M ; Vakilian, M ; Mortazavi, S. S ; Sharif University of Technology
    Elsevier Ltd  2016
    Abstract
    Accurate Partial Discharge (PD) measurement requires the expansion of the measurement frequency range to Ultra High Frequency (UHF) band. For this it is needed to implement modern techniques when monitoring an important element of power system, such as power transformer. Different kind of experimental models, such as insulation defect models, and the complete transformer windings models are used to simulate the partial insulation failure situations which occur in a real transformer. However, since in these models, some kind of simplifications are employed which may result in an electromagnetic waves (EM) propagation pattern different from what exists in a real transformer and encounter... 

    Accurate power transformer PD pattern recognition via its model

    , Article IET Science, Measurement and Technology ; Volume 10, Issue 7 , 2016 , Pages 745-753 ; 17518822 (ISSN) Rostaminia, R ; Sanie, M ; Vakilian, M ; Mortazavi, S. S ; Parvin, V ; Sharif University of Technology
    Institution of Engineering and Technology  2016
    Abstract
    In this study, a transformer model is proposed to simulate the behaviour of a real transformer, under presence ofdifferent types of defects which contribute to partial discharge (PD) generation, as closely as possible. Five different typesof defects (scratch on winding insulation, bubble in oil, moisture in insulation paper, very small free metal particle intransformer tank and fixed sharp metal point on transformer tank) are implemented artificially into these transformermodels to investigate the resultant PD current signal magnitude and characteristics. Time-domain PD currentwaveforms are recorded on those transformer models which have one type of those defects. The resultant statisticalPD... 

    The synergistic effect of surface topography and sustained release of TGF-β1 on myogenic differentiation of human mesenchymal stem cells

    , Article Journal of Biomedical Materials Research - Part A ; Volume 104, Issue 7 , 2016 , Pages 1610-1621 ; 15493296 (ISSN) Moghadasi Boroujeni, S ; Mashayekhan, S ; Vakilian, S ; Ardeshirylajimi, A ; Soleimani, M ; Sharif University of Technology
    John Wiley and Sons Inc  2016
    Abstract
    A combination of topographical cues and controlled release of biochemical factors is a potential platform in controlling stem cells differentiation. In this study the synergistic effect of nanotopography and sustained release of biofunctional transforming growth factor beta 1 (TGF-β1) on differentiation of human Wharton's Jelly-derived mesenchymal stem cell (hWJ-derived UC-MSCs) toward myogenic lineage was investigated. In order to achieve a sustained release of TGF-β1, this factor was encapsulated within chitosan nanoparticles. Afterwards the aligned composite mats were fabricated using poly-E-caprolacton (PCL) containing TGF-β1-loaded chitosan nanoparticles and poly-L-lactic acid (PLLA).... 

    An efficient partial discharge pattern recognition method using texture analysis for transformer defect models

    , Article International Transactions on Electrical Energy Systems ; Volume 28, Issue 7 , February , 2018 ; 20507038 (ISSN) Rostaminia, R ; Saniei, M ; Vakilian, M ; Mortazavi, S. S ; Parvin Darabad, V ; Sharif University of Technology
    John Wiley and Sons Ltd  2018
    Abstract
    Partial discharge (PD) measurement is one of the best methods for condition monitoring of transformers. In this paper, we use 5 different types of defects as follows: scratch on winding insulation, bubble in oil, moisture in insulation paper, a very small free metal particle in the transformer tank, and a fixed sharp metal point on the transformer tank, for our PD-related studies. Each type of defect is implemented into 1 of the 5 identical transformer models, which had been developed in the authors' recent work. The continuous wavelet transform is applied to each related measured time-domain PD signals. This process results in an image, for each PD pulse in the time-frequency domain. Using... 

    Optimal placement of fast charging station in a typical microgrid in Iran

    , Article International Conference on the European Energy Market, EEM ; 2013 ; 21654077 (ISSN); 9781479920082 (ISBN) Rastegarfar, N ; Kashanizadeh, B ; Vakilian, M ; Barband, S. A ; Sharif University of Technology
    2013
    Abstract
    In this work a microgrid is established within the geographical perspective of interest. The characteristics of the grid and its urban are employed to determine the candidate points for establishment of EV charging stations. The investment costs and operation costs are calculated for each station realizing the required constraints. This process resulted in optimum selection of EV stations. The optimization is achieved based on two different types of preliminary assumptions. In the first one, it is assumed to have only one station, while in the second one possibility of having multi-stations is considered. Using the total investment and operation costs as the objective function of... 

    Implementing distance line protection schemes among IEC61850-enabled substations

    , Article Proceedings of the IEEE Power Engineering Society Transmission and Distribution Conference ; April , 2014 , Page(s): 1 - 5 ; ISSN: 21608555 ; ISBN: 9781479936557 Falahati, B ; Darabi, Z ; Vakilian, M
    2014
    Abstract
    As digital technology has developed, relays have evolved from simple electro-mechanical devices into robust microprocessor-embedded intelligent electronic devices (IEDs). Distance protection, one of the most important and sophisticated forms of substation protection, quickly and selectively detects and clears phase faults in sub-transmission and transmission lines. The installation of a substation automation system (SAS) involves implementing control, monitoring, and protection logic by programming the IEDs and providing an appropriate communication network. IEC61850 has gradually satisfied the need for a standard communication protocol so that IEDs from different manufacturers can... 

    Determination of installation capacity in reservoir hydro-power plants considering technical, economical and reliability indices

    , Article International Journal of Electrical Power and Energy Systems ; Volume 30, Issue 6-7 , 2008 , Pages 393-402 ; 01420615 (ISSN) Hosseini, S. M. H ; Forouzbakhsh, F ; Fotouhi, M ; Vakilian, M ; Sharif University of Technology
    2008
    Abstract
    One of the most important issues in planning the "reservoir" type of hydro-power plants (HPP) is to determine the installation capacity of the HPPs and estimate its annual energy value. In this paper, a method is presented. A computer program has been developed to analyze energy calculation and estimation of the most important economic indices of an HPP using the sensitivity analysis method. Another program, developed by Matlab software, calculates the reliability indices for a number of units of an HPP with a specified load duration curve using the Monte Carlo method. Ultimately, comparing the technical, economic and reliability indices will determine the installation capacity of an HPP. By... 

    Educational robot for principles of electrical engineering

    , Article Scientia Iranica ; Volume 25, Issue 3D , 2018 , Pages 1582-1592 ; 10263098 (ISSN) Rahnavard, M ; Alavi, M. H ; Khorasani, S ; Vakilian, M ; Fardmanesh, M ; Sharif University of Technology
    Sharif University of Technology  2018
    Abstract
    An educational robot is described, which is designed and constructed for use in the laboratory of Principles of Electrical Engineering. The discrete nature of design, conforming to a simple block strategy, allows for fairly easy introduction of basic and fundamental concepts of Electrical Engineering to the freshman students, including control, actuation, wireless signal transmission, and analogue/digital conversions. Each block or module represents one or few engineering ideas and helps the students to understand the interplay and connection between system divisions, and enhance their creative thinking. Circuits are designed and implemented such that both structure and functionality of each... 

    Evaluation of Electromagnetic Forces on three-phase Core-Type Power Transformer Windings during Inrush Current by FEM

    , M.Sc. Thesis Sharif University of Technology Eslami, Ali (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Inrush Current is a form of over-current that occurs during energization of a transformer. For power transformers, the magnitude of the first peak of inrush current is initially several times the rated load current but slowly decreases until it finally reaches the normal exciting current value. This process typically takes several minutes. Time-variant axial and radial electromagnetic forces under inrush current and short-circuit current are calculated (by finite element method; FEM), and compared. An analytic method is presented for computation of inrush current in transformer. The simulation results obtained by this proposed method are compared with the measured values. A compact... 

    Modeling and Data Mining of Partial Discharge in Power Transformer Solid Insulation

    , M.Sc. Thesis Sharif University of Technology Jahangir, Hamid (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Transformers are one of the most important equipments in transmission and distribution networks. Transformer unplanned outages have severe impacts on the continuity of power system operation. To improve the reliability of transformers and to achieve an optimum operation cost, online condition monitoring of transformers is inevitable. Information about the quality of the transformers insulation system is known as the best parameter to be monitored in a transformer. Since partial discharge signals are initiated long before the beginning of a severe damage, partial discharge monitoring and its evaluation canbe employed to warn the operator.Data mining on the partial discharge signals extracts... 

    Designing an Automated and Smart Electric Power Distribution System

    , M.Sc. Thesis Sharif University of Technology Ameli, Amir (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Feeder reconfiguration is one of the most prominent tasks for loss reduction, reliability improvement and also congestion alleviation in distribution networks. Besides improving abovementioned operational issues, during a long period of time, proper switching in appropriate times can causes a lot of economic savings. Furthermore, it can be intensified when capacitors are implemented and controlled in the network. To reach this purpose, most of the previous literature focuses merely on the power grid reconfiguration. Few of these researches have considered this problem as a dynamic one and studied that in a period of time, e.g. one day, considering fixed level of loads despite the others that... 

    Optimal Placement of fault Indicator and Switch in Distribution Network Simultaneously

    , M.Sc. Thesis Sharif University of Technology Salehi, Saber (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    The price that customers pay for electric energy is determined by cost of generation, transmission and distribution parts. In Practice all customer have main concern about reliability of electric energy, because of it’s major effect on different aspect of life. Although customers are interested to have fully reliable service, but power companies are aware that it is impossible to achieve this goal from technical and economical aspect. The utilities and customer benefits can be achieved through minimization of the total investment cost of network, while improving the reliability and quality of electric service. This also requires to minimize the customers service interruption time. To meet... 

    Design of a Modern Compact Transmission Line for Electrical Energy Transmission in Long Distances at 400 kV

    , M.Sc. Thesis Sharif University of Technology Karami, Marzie (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    With new progresses in technology, a growing need to power energy has emerged. In Iran most of power plants are far from cities and therefore expansion of power network will cause long transmission lines with high capacities which connect power plants to cities. There are three solutions for these kinds of lines: 1) two-circuit transmission lines 2) higher voltages 3) new forms of transmission lines (HVDC and compact). In this thesis some of these suggestions have been analyzed to find the best solution for a 560 Km transmission line in Iran.
    Designing transmission lines has a lot of steps which all are related to each other. In this project a comprehensive algorithm has been utilized to... 

    A Novel Islanding Detection Method For Micro Grids

    , M.Sc. Thesis Sharif University of Technology Mohiti, Maryam (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    There is an increasing trend nowadays toward Distributed Generation (DGs). DG poses positive and negative side effects for both utility and customers. Reduction of system expansion costs, decreasing power loss and reliability enhancement are some benefits of DGs. Connecting DGs to the distribution system can lead to some troublesome issues. Anti-islanding protection is one of these issues. Islanding is the situation in which a distribution system becomes electrically isolated from the remainder of the power system, yet continues to be energized by DG connected to it. Traditionally, a distribution system doesn’t have any active power generating source in it and it doesn’t get power in case... 

    Reconfiguration and Capcitor Placement in Distribution Systems for Loss Reduction and Reliability Enhancement

    , M.Sc. Thesis Sharif University of Technology Rezaei, Pooya (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Capacitor setting and reconfiguration are of main means of loss reduction and voltage profile improvement in distribution system operation. Cooperation between these two strategies can effectively minimize power losses in distribution system automation. Also, from the medium and long term viewpoint, capacitor placement and reconfiguration can be used for loss reduction and reliability enhancement. In this section, the sum of losses cost, capacitor investment cost and reliability cost should be minimized. Regarding the need to solve two non-linear combinatorial optimization problems simultaneously, metaheuristic algorithms are used in this thesis. Specifically, Elitist Genetic Algorithm,... 

    Development a Numerical Algorithm for Differential Relay for Transformer Protection

    , M.Sc. Thesis Sharif University of Technology Gholami, Mohammad (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    The goal of this master thesis is to develop a new accurate numerical algorithm for digital differential relay to protect a power transformer. This work employs specially developed software to simplify its input signal processing task which helps to quickly and accurately detect and clear the transformer internal faults. The available commercial transformer digital differential relays lack the required sensitivity to detect turn to turn faults when a few numbers of turns (less than 10% of the winding) are involved. This work presents a new equivalent circuit for transformer when a turn to turn fault occurs on either winding. This equivalent circuit helped to develop an accurate algorithm for... 

    Instant of Protective CT Saturation and its Compensation

    , M.Sc. Thesis Sharif University of Technology Borzooy, Amir (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    The purpose of carrying out this Master thesis is to detect occurrence of CT saturation which leads to consecutive failures in operation of protective current transformers, as a major component in protection of power systems. The protective relay installed in the secondary side of the protective CT fails to act properly under occurrence of this phenomenon, and it doesn’t reflect proportionally the high value of fault currents passing through CT’s primary winding. As a consequence, faults become undetectable. Meanwhile, the proposed methods for detection of CT saturation must be reliable under a noisy condition, realizing that power systems have some inherent noises always available in the... 

    Design of a SF6 Load Breaker Switch for Compact Distribution Substation

    , M.Sc. Thesis Sharif University of Technology Akbari, Mohammad (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Electrical energy customer and load growth on the one hand and the problems of allocation of land for the development of the power networks on the other hand, make the tendency to use less space in the electrical industries. One of the solutions used in power distribution networks, especially in crowded areas is compact substation which requires less space than ordinary substations and also the prefabricated types of this substation can be used in the distribution system. In a compact distribution substation, all components must be designed with a minimum size. Therefore, the insulation system of the compact substation should be designed based on these requirements.
    In the distribution... 

    Identification of Conductive Particles in Transformer Oil Model using Partial Discharge Signal

    , M.Sc. Thesis Sharif University of Technology Firuzi, Keyvan (Author) ; Vakilian, Mehdi (Supervisor)
    Abstract
    Transformer are one of the most important equipment in transmission and distribution network. Transformer unplanned outage have severe impacts on the continuity of power system operation and is also an irreparable economic harm to power network operators. To improve the reliability of transformers and to achieve an optimum operation cost, online condition monitoring is inevitbale. Information about the quality of the transformer insulation system is known as the best parameter to be monitored in transformer. Since partiale discharge (PD) signals are initiated long before the beginning of a severe damage, monitoring and its evaluation can be employed to warn the operator. Data mining on the...