Loading...
Search for:
shabany--m
0.136 seconds
Total 21512 records
A low-power 10-Bit 40-MS/s pipeline ADC using extended capacitor sharing
, Article Proceedings - IEEE International Symposium on Circuits and Systems ; 1- 5 June , 2014 , pp. 1147-1150 ; ISSN: 02714310 ; Sharifkhani, M ; Shabany, M ; Sharif University of Technology
2014
Abstract
This paper describes a new capacitor sharing technique for pipeline ADCs. It enables power reduction of the first and second MDACs simultaneously. The presented noise and power analysis shows that the proposed method is about 30% more efficient than the conventional one in terms of the first and second MDACs power dissipation. A 10-bit 40MS/s pipeline ADC employing the proposed technique was designed in 90-nm CMOS technology achieving a power consumption of 4.2 mW
An efficient VLSI architecture of QPP interleaver/deinterleaver for LTE turbo coding
, Article Proceedings - IEEE International Symposium on Circuits and Systems ; 2013 , Pages 797-800 ; 02714310 (ISSN) ; 9781467357609 (ISBN) ; Mahdavi, M ; Shabany, M ; Sharif University of Technology
2013
Abstract
Long Term Evolution (LTE) supports peak data rates in excess of 300 Mb/s. A good approach to achieve such rates is by parallelizing the required processing in turbo decoders. An interleaver is an important part of a turbo decoder. LTE uses the Quadratic Permutation Polynomial (QPP) interleaver, which makes it suitable for parallel decoding. In this paper, we propose an efficient architecture for the QPP interleaver, called the Add-Compare-Select (ACS) permuting network. A unique feature of the proposed architecture is that it can be used both as the interleaver and deinterleaver leading to a high-speed low-complexity hardware interleaver/deinterleaver for turbo decoding. The proposed design...
Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time
, Article IEEE Transactions on Instrumentation and Measurement ; Volume 66, Issue 12 , 2017 , Pages 3299-3308 ; 00189456 (ISSN) ; Kachuee, M ; Shabany, M ; Sharif University of Technology
2017
Abstract
This paper presents a novel blood pressure (BP) estimation method based on pulse transit time (PTT) and pulse arrival time (PAT) to estimate the systolic BP (SBP) and the diastolic BP (DBP). A data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG), photoplethysmogram, and electrocardiogram (ECG). PCG and ECG perform as the proximal timing reference to obtain PTT and PAT indices, respectively. In order to derive a BP estimator model, a calibration procedure, including a supervised physical exercise, is conducted for each individual, which causes changes in their BP, and then, a number of reference BPs are measured alongside the acquisition of the signals...
A practical ACO-OFDM link with an efficient timing recovery pattern
, Article 2023 31st International Conference on Electrical Engineering, ICEE 2023 ; 2023 , Pages 690-693 ; 979-835031256-0 (ISBN) ; Johar, M ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2023
Abstract
In this paper, to increase the accuracy of estimating timing offset for asymmetrically-clipped optical orthogonal frequency division multiplexing (ACO-OFDM) systems, we introduce a new frame synchronization pattern, where repetition in the time domain is used to build the new training pattern. Simulation results prove that the suggested frame synchronization provides an exact approximation of the symbol timing. © 2023 IEEE
Non-invasive blood pressure estimation using phonocardiogram
, Article Proceedings - IEEE International Symposium on Circuits and Systems, 28 May 2017 through 31 May 2017 ; 2017 ; 02714310 (ISSN) ; 9781467368520 (ISBN) ; Kachuee, M ; Shabany, M ; Sharif University of Technology
2017
Abstract
This paper presents a novel approach based on pulse transit time (PTT) for the estimation of blood pressure (BP). In order to achieve this goal, a data acquisition hardware is designed for high-resolution sampling of phonocardiogram (PCG) and photoplethysmogram (PPG). These two signals can derive PTT values. Meanwhile, a force-sensing resistor (FSR) is placed under the cuff of the BP reference device to mark the moments of measurements accurately via recording instantaneous cuff pressure. For deriving the PTT-BP models, a calibration procedure including a supervised physical exercise is conducted for each individual. The proposed method is evaluated on 24 subjects. The final results prove...
Improved CT image reconstruction through partial Fourier sampling
, Article Scientia Iranica ; Volume 23, Issue 6 , 2016 , Pages 2908-2916 ; 10263098 (ISSN) ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
Sharif University of Technology
2016
Abstract
A novel CT imaging structure based on Compressive Sensing (CS) is proposed. The main goal is to mitigate the CT imaging time and, thus, X-ray radiation dosage without compromising the image quality. The utilized compressive sensing approach is based on radial Fourier sampling. Thanks to the intrinsic relation between captured radon samples in a CT imaging process and the radial Fourier samples, partial Fourier sampling could be implemented systematically. This systematic compressive sampling helps in better control of required conditions such as incoherence and sparsity to guarantee adequate image quality in comparison to previous CS-based CT imaging structures. Simulation results prove the...
Improved-resolution millimeter-wave imaging through structured illumination
, Article Applied Optics ; Volume 56, Issue 15 , 2017 , Pages 4454-4465 ; 1559128X (ISSN) ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
2017
Abstract
A resolution-improved active millimeter-wave (MMW) imaging structure, based on the theory of structured illumination, is proposed in this paper. The structured illumination is a well-defined concept for surpassing the diffraction limit in optical microscopy, where imposing grating patterns on the targeted object could help in moving the object frequency spectrum along the desired direction in the spatial frequency domain. This frequency shift helps in passing different parts of the object's frequency spectrum through the diffraction filter. The combination of resultant images provides a framework to pass a wider frequency band of the object, thereby achieving super-resolution. This idea has...
K-Space aware multi-static millimeter-wave imaging
, Article IEEE Transactions on Image Processing ; Volume 28, Issue 7 , 2019 , Pages 3613-3623 ; 10577149 (ISSN) ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2019
Abstract
This paper focuses on an efficient approach for designing multi-static arrays for millimeter-wave imaging, based on the k -space or Fourier-spatial domain characteristic of imaging systems. Our goal is to decrease the redundancy of the data measured by each antenna and to improve the resolution of the reconstructed image. The proposed technique is based on determining the role of each transmitter and receiver, in collecting the data from each voxel of the target in k -space domain and then rotating the transmitters' beams to measure the desirable information. The effect of non-uniform redundant k -space domain frequency samples that act as an undesirable filter is compensated using a...
K-Space analysis of aliasing in millimeter-wave imaging systems
, Article IEEE Transactions on Microwave Theory and Techniques ; Volume 69, Issue 3 , 2021 , Pages 1965-1973 ; 00189480 (ISSN) ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2021
Abstract
This article focuses on analyzing the aliasing artifact in millimeter-wave imaging systems, with a special focus on multistatic arrays. The current framework to analyze the behavior of multistatic structures is based on the effective aperture concept. Based on this framework, an equivalent monostatic array, approximating the position of each transmitter-receiver pair by its midpoint, is used to quantify the response and efficiency of the system. Although this framework helps to simplify the study of the complex characteristics of multistatic arrays, it suffers from vital deficiencies. Especially, it fails to describe the aliasing artifacts, seen in the image of some sparse multistatic...
Cuffless blood pressure estimation algorithms for continuous health-care monitoring
, Article IEEE Transactions on Biomedical Engineering ; Volume 64, Issue 4 , 2017 , Pages 859-869 ; 00189294 (ISSN) ; Kiani, M. M ; Mohammadzade, H ; Shabany, M ; Sharif University of Technology
IEEE Computer Society
2017
Abstract
Goal: Continuous blood pressure (BP) monitoring can provide invaluable information about individuals' health conditions. However, BP is conventionally measured using inconvenient cuff-based instruments, which prevents continuous BP monitoring. This paper presents an efficient algorithm, based on the pulse arrival time (PAT), for the continuous and cuffless estimation of the systolic BP, diastolic blood pressure (DBP), and mean arterial pressure (MAP) values. Methods: The proposed framework estimates the BP values through processing vital signals and extracting two types of features, which are based on either physiological parameters or whole-based representation of vital signals. Finally,...
Thorough approach toward cylindrical MMW image reconstruction using sparse antenna array
, Article IET Image Processing ; Volume 12, Issue 8 , 2018 , Pages 1458-1466 ; 17519659 (ISSN) ; Seyyed Talebi, M. J ; Kazemi, M ; Kavehvash, Z ; Shabany, M
Institution of Engineering and Technology
2018
Abstract
In this study, a thorough analysis of image reconstruction in an active millimetre-wave (MMW) cylindrical imaging system is performed. To improve the system's performance in terms of the total cost as well as the coupling effect, sparse multistatic arrays are desired. Nevertheless, the existing reconstruction methods fail to operate in sparse multi-static antenna-array systems. Therefore, to address these shortcomings, in this study, at first, the existing MMW mono-static cylindrical image reconstruction methods are modified in both single-frequency and wideband reconstruction platforms. Moreover, in order to further improve the image quality and the system cost, a sparse multi-static...
Accurate single-trial detection of movement intention made possible using adaptive wavelet transform
, Article Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 25 August 2015 through 29 August 2015 ; Volume 2015-November , 2015 , Pages 1914-1917 ; 1557170X (ISSN) ; 9781424492718 (ISBN) ; Malekmohammadi, A ; Bahrani, M ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2015
Abstract
The outlook of brain-computer interfacing (BCI) is very bright. The real-time, accurate detection of a motor movement task is critical in BCI systems. The poor signal-to-noise-ratio (SNR) of EEG signals and the ambiguity of noise generator sources in brain renders this task quite challenging. In this paper, we demonstrate a novel algorithm for precise detection of the onset of a motor movement through identification of event-related-desynchronization (ERD) patterns. Using an adaptive matched filter technique implemented based on an optimized continues Wavelet transform by selecting an appropriate basis, we can detect single-trial ERDs. Moreover, we use a maximum-likelihood (ML),...
Fourier photoacoustic microscope improved resolution on single-pixel imaging
, Article Applied Optics ; Volume 61, Issue 5 , 2022 , Pages 1219-1228 ; 1559128X (ISSN) ; Amjadian, M ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
The Optical Society
2022
Abstract
A new single-pixel Fourier photoacoustic microscopy (PAM), to the best of our knowledge, is proposed to improve the resolution and region of interest (ROI) of an acquired image. In the previous structure of single-pixel Fourier PAM, called spatially invariant resolution PAM (SIR-PAM), the lateral resolution and ROI are limited by the digital micromirror device (DMD) pixel size and the number of pixels. This limitation is overcome here through illuminating fixed angle interfering plane waves, changing the fringe frequency via varying the frequency of the laser source. Given that the fringe sinusoidal patterns here can be produced by two mirrors, the DMD usage can be omitted. In this way, the...
Efficient implementation of real-time ECG derived respiration system using cubic spline interpolation
, Article Proceedings - IEEE International Symposium on Circuits and Systems ; 2013 , Pages 1083-1086 ; 02714310 (ISSN) ; 9781467357609 (ISBN) ; Ehsani, S. P ; Shabany, M ; Sharif University of Technology
2013
Abstract
Monitoring the respiratory signal is crucial in many medical applications. Traditional methods for the respiration measurement are normally based on measuring the volume of air inhaled and exhaled by lungs (like spirometer) or oxygen saturation in blood. However, these methods have numerous challenges including their high cost and not being accessible in some cases. In this paper, an algorithm for deriving the respiratory signal from ECG signal is proposed, which is based on other proposed algotithms. This algorithm uses the cubic spline interpolation (CSI) of R-waves in ECG to derive the respiratory signal. The CSI algorithm is made efficient with respect to ECG features in order to reduce...
Efficient millimetre-wave imaging structure for detecting axially rotated objects
, Article IET Microwaves, Antennas and Propagation ; Volume 12, Issue 3 , 2018 , Pages 416-424 ; 17518725 (ISSN) ; Kavehvash, Z ; Shabany, M ; Sharif University of Technology
Institution of Engineering and Technology
2018
Abstract
An efficient multi-static millimetre-wave (MMW) imaging system is proposed with the aim of obtaining the information of an axially tilted object. It is known that a multi-static structure performs better than a mono-static array in detecting the reflected signal from axially tilted surfaces due to the specular reflection. Still, no efficient multi-static structure for the purpose of imaging tilted objects in view of the computational time, cost and image quality is proposed till now. The authors propose an efficient multi-static MMW imaging system tackle this issue with the minimum number of antennae. Furthermore, the small number of antennae in the proposed design and the proposed fast...
An efficient architecture for Sequential Monte Carlo receivers in wireless flat-fading channels
, Article Journal of Signal Processing Systems ; Volume 68, Issue 3 , 2012 , Pages 303-315 ; 19398018 (ISSN) ; Sharif University of Technology
Springer New York LLC
2012
Abstract
A pipelined architecture is developed for a Sequential Monte Carlo (SMC) receiver that performs joint channel estimation and data detection. The promising feature of the proposed SMC receiver is achieving the near-bound performance in fading channels without using any decision feedback, training or pilot symbols. The proposed architecture exploits the parallelism intrinsic to the algorithm and consists of three blocks, i.e., the SMC core, weight calculator, and resampler. Hardware efficient/parallel architectures for each functional block including the resampling block is developed. The novel feature of the proposed architecture is that makes the execution time of the resampling independent...
A low complexity architecture for the cell search applied to the LTE systems
, Article 2012 19th IEEE International Conference on Electronics, Circuits, and Systems, ICECS 2012, 9 December 2012 through 12 December 2012 ; Dec , 2012 , Pages 300-303 ; 9781467312615 (ISBN) ; Sharifan, G ; Amini, Y ; Shabany, M ; Sharif University of Technology
2012
Abstract
Cell search is a crucial process in the synchronization procedure for the 3rd Generation Partnership Project (3GPP) Long Term Evolution (LTE) system. In this paper, a high-speed, low-complexity and reliable architecture is proposed for both steps of cell search: sector ID and cell ID group detection. For the sector ID detection, two novel methods, sign-bit reduction and wise resource sharing, are proposed. In addition, for the cell ID group detection, we proposed an algorithm based on the Maximum Likelihood Sequence Detection (MLSD) called 'sign-bit MLSD'. Simulations show that the proposed methods result in more than 90% reduction in area compared to the state-of-the-art. We designed and...
Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time
, Article Proceedings - IEEE International Symposium on Circuits and Systems, 24 May 2015 through 27 May 2015 ; Volume 2015-July , 2015 , Pages 1006-1009 ; 02714310 (ISSN) ; 9781479983919 (ISBN) ; Kiani, M.M ; Mohammadzade, H ; Shabany, M ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2015
Abstract
Recently a few methods have been proposed in the literature for non-invasive cuff-less estimation of systolic and diastolic blood pressures. One of the most prominent methods is to use the Pulse Transit Time (PTT). Although it is proven that PTT has a strong correlation with the systolic and diastolic blood pressures, this relation is highly dependent to each individuals physiological properties. Therefore, it requires per person calibration for accurate and reliable blood pressure estimation from PTT, which is a big drawback. To alleviate this issue, in this paper, a novel method is proposed for accurate and reliable estimation of blood pressure that is calibration-free. This goal is...
Critical object recognition in millimeter-wave images with robustness to rotation and scale
, Article Journal of the Optical Society of America A: Optics and Image Science, and Vision ; Volume 34, Issue 6 , 2017 , Pages 846-855 ; 10847529 (ISSN) ; Ghojogh, B ; Faezi, S ; Shabany, M ; Sharif University of Technology
OSA - The Optical Society
2017
Abstract
Locating critical objects is crucial in various security applications and industries. For example, in security applications, such as in airports, these objects might be hidden or covered under shields or secret sheaths. Millimeter-wave images can be utilized to discover and recognize the critical objects out of the hidden cases without any health risk due to their non-ionizing features. However, millimeter-wave images usually have waves in and around the detected objects, making object recognition difficult. Thus, regular image processing and classification methods cannot be used for these images and additional pre-processings and classification methods should be introduced. This paper...
Fast fourier-based implementation of synthetic aperture radar algorithm for multistatic imaging system
, Article IEEE Transactions on Instrumentation and Measurement ; 2018 ; 00189456 (ISSN) ; Shayei, A ; Shabany, M ; Kavehvash, Z ; Sharif University of Technology
Institute of Electrical and Electronics Engineers Inc
2018
Abstract
Multistatic millimeter-wave imaging structures are superior to their monostatic counterparts for imaging natural objects of sudden profile variations. Multistatic image reconstruction is conventionally performed via synthetic aperture radar (SAR)-based methods which, in spite of their high accuracy, are computationally burdensome. On the other side, the Fourier-based image reconstruction in multistatic systems also faces few challenges including multidimensional interpolation, a plane-wave approximation of spherical waves, and k-space partitioning. This paper presents a fast implementation of the SAR-based image reconstruction method in case of 1-D and 2-D multistatic arrays. The proposed...